Indicative Test Results - Roofing Slate

Tests Standard Penrhyn Capital 6mm Trinity 4-6mm Glendyne 4-5mm Cupa R6 4-5mm World's Best Bmks
Water Absorption (%) ASTM C121-06 0.19 0.25 0.21 0.29 < 0.25
Durability Grade (S1, S2 or S3) ASTM C406-06 S1 S1 S1 S1 S1
Service Life (years) ASTM C406-06 75+ 75+ 75+ 75+ 75+
Modulus of Rupture (MPa) - longitudinal EN 12326-1:2004 91 85 77 74 > 62
Carbon content (%) EN 12326-1:2004 < 0.1 0.38 0.61 0.59 -
Non carbon content (%) EN 12326-1:2004 - 0.5 0.99 0.3 < 2
Absorption Class (A1, A2 or A3) EN 12326-1:2004 A1 A1 A1 A1 A1
Freeze Thaw Test Class (T1, T2 or T3) EN 12326-1:2004 T1 T1 T1 T1 T1
Sulphur Dioxide Exposure Class (S1, S2 or S3) EN 12326-1:2004 S1 S1 S1 S1 S1
­