Indicative Test Results - Stone for Flooring & Walls

Notice to Architects, Specifiers & Estimators

The test results presented below were conducted by Jim Mann, Stone Initiatives MTG, South Australia - original copies in pdf format are available upon request.

Click here for a free project consultation

Resistance to Salt Attack (AS/NZS 4456:10-2003 Method A)

(This test is also a very good indicator of durability under all conditions)

 Stone Product
 Weight Loss %  Classification   Mode of Decay - Explanation
Willow sandstone 0.2 A  no decay visible
Bellandra sandstone 0.4 A  very slight surface pitting
Coogee sandstone
1.4
B
 slight surface pitting
Grey Gum quartzite 0.05 AA  no decay visible
Sofala quartzite 0.05 AA  no decay visible
Classico travertine
0.04
AA
 very slight surface pitting
Mocha travertine
0.3
A
 slight surface pitting
Bellambi bluestone 0.18 A  very slight surface pitting
Mali bluestone
0.08
AA
 no decay visible

 
NB The benchmarks for use of stone around salt water pools is 0.1% weight loss or less


Bulk Specific Gravity (Density) (ASTM C97-02)

 Stone Product
 Bulk Specific Gravity
(Kg/m3)
ASTM C616
 Benchmarks Kg/m3 (min)

Alba Grey marble
2716
2595  (ASTM C503-08)
Willow sandstone 2421 2003
Bellandra sandstone 2421 2003
Coogee sandstone
2063
2003
Grey Gum quartzite 2720 2560
Sofala quartzite 2718 2560
Classico travertine
2463
2305
Mocha traveritne
2416
2305
Bellambi bluestone 2802 2560
Mali bluestone
2895
2560
Chinese Black slate 2753
-
Chinese North Country slate 2714
-
Chinese Sunrise slate 2699
-

Click here for a free project consultation


Water Absorption (ASTM C97-02)

 Stone Product
Water Absorption
by weight %

Water Absorption
by volume % (porosity)

ASTM C616 Benchmarks
by weight % (max)
Alba Grey marble
0.12
-
0.20 (ASTM C503-08)
Willow sandstone 2.2 5.3
8.0
Bellandra sandstone 2.8 6.8
8.0
Coogee sandstone
5.9
12.2
8.0
Grey Gum quartzite 0.05 0.17
3.0
Sofala quartzite 0.06 0.18
3.0
Classico travertine
1.1
2.8
2.5
Mocha travertine
1.8
-
2.5
Bellambi bluestone 1.16 3.25
Mali bluestone
0.49
1.4

Chinese Black slate 0.23
0.63
0.25 (exterior) & 0.45 (interior) (ASTM C629-08)
Chinese North Country slate 0.66
1.78
0.25 (exterior) & 0.45 (interior) (ASTM C629-08)  
Chinese Sunrise slate 0.71
1.91
0.25 (exterior) & 0.45 (interior) (ASTM C629-08)  


Flexural Strength (ASTM C880-98)

 Stone Product
 Flexural  Strength Dried MPa
 Flexural  Strength Wet MPa 
Benchmarks
Alba Grey marble
18.1
12.2
7.0 (ASTM C615)
Willow sandstone 19.4 16.1
Bellandra sandstone 15.6 13.5
Coogee sandstone
8.3
5.8

Grey Gum quartzite 22.6 26 6.9 (ASTM C616)
Sofala quartzite 21.7 23.7 6.9 (ASTM C616)
Classico travertine
17.9
17.8

Mocha traverine
16.4
13.6

Bellambi bluestone 30.7 24.0 10.34
Mali bluestone
22.8
18.1
10.34
Chinese Black slate 29.3
22.6

Chinese North Country slate 37.7
24.6

Chinese Sunrise slate 26.5
27.9

Click here for a free project consultation


Breaking Load of Segmental Pavers (AS/NZS 4456.5-2003)


Modulus of Rupture Strength MPa
Bellambi bluestone 27.1

 

Slip Resistance - Wet Pendulum Test (AS/NZS 4586:2004)

 Stone Product
 Slip Resistance 
mean BPN
 Risk of Slipping 
Classification
 Risk of Slipping 
Assessment
Alba Grey marble
31
Y
High
Willow sandstone (natural split) 65 V very low
Willow sandstone (honed)
60
V
very low
Bellandra sandstone 56 V very low
Coogee sandstone - s/blasted
73
V
very low
Coogee sandstone - sawn
67
V
very low
Grey Gum quartzite 52 W low
Sofala quartzite 52 W low
Classico travertine (honed)
36
X
moderate
Classico travertine (tumbled)
40
X
moderate
Mocha travertine (honed)
34
Y
high
Arctic Green slate 53 W low
Chinese Black slate
56 V
very low
Chinese North Country slate
49
W
low
Chinese Sunrise slate
53
W
low
Bellambi bluestone - flamed 50 W low
Bellambi bluestone - honed 37 X moderate/high
Bellambi bluestone - polished 19 Z very high
Mali bluestone - flamed
60
V
very low
Mali bluestone - honed
32
Y
high

Architects - AS HB197 may be used to approximate Oil Ramp test R values - there is no conversion table as the tests are vastly different. On this basis, V (on the more relevant & less costly wet pendulum test) is closely aligned with R11 and X with R10.

Interpretation of Slip Resistance Tests
(Reference AS HB197:1999)

 Location Suitability
 V ( equivalent to R11 - AS HB197)
 W
External colonnade, walkways & pedestrian crossings
Yes Yes
Swimming pool surrounds & communal  showers
Yes Yes
Shopping centres including food courts
Yes
Yes
Undercover concourses of sports stadiums
Yes No
Entry foyers hotel, office, public  buildings - wet
Yes Yes
External stair nosings & ramps
Yes
No
Toilet facilities in offices, hotels & shopping centres
Yes No


Data Source - Stone Initiatives + Materials Testing Group Pty Ltd. South Australia & CSIRO
­